The Design and Supply of a 120kVA Emergency Standby Diesel Generator for use on an FPSO operating in Africa.
Specification
Client defined specification and operating criteria including Local / Remote Operation with synchronising facility.
- Unit designed and packaged within a DNV 2.7.1 Lifting frame with High Ingress Protection to IP56.
- Dual Primary Battery Start Systems and Secondary Hydraulic Start.
- Extended Service Interval with automatic lubricating Oil Top Up System.
- Electrically Operated Inlet and Outlet Dampers.
- Client Specific Generator Control System mounted within an Ex d Control Panel.
- Ex d Battery Isolators
- Ex d Heat, Smoke and Gas Detection System.
- Designed packaged and fully tested in U.K.
- Shipped to Africa and installed tested and fully commissioned at site.