image RIGSAFE MD 275kVA image PROJECT SPECIFIC — 1500kVA Gas & Diesel

ZONE 2 PT- 200KVA UNMANNED PLATFORM / N.U.I.

Zone 2 PT 200kVA-1

2 X 200kVA Main Power Diesel Generators for use on Unmanned Offshore Installations / NUI in Africa.

Specification

  • Engine with Explosion proof conversion in accordance with ATEX Zone 2 Directive Gas Groups IIA and IIB, Temp Class T3
  • Intake air, explosion proof manifold and shutdown valve, with integrated flame arrestor
  • Exhaust, explosion proof manifold, with integrated flame arrestor
  • Exhaust water jacketed coolers and piping
  • Overspeed Valve
  • Spark arrestor mounted towards the end of the exhaust pipe
  • Customized radiator with fan
  • Anti static engine belts
  • Alternator for use in Zone 2 Hazardous Areas Gas Groups IIA and IIB, Temp Class T3
  • Integral fuel tank allowing a minimum of 12 hrs running @ 100% load
  • Weatherproof Sound Attenuated enclosure to 85dBA @ 1 metre
  • Dual Primary Electrical Start System.
  • Comap Intelligen Controller Module mounted in ATEX Compliant Ex d Generator Control Panel.
  • Remote Control Station with Comap HMI
  • Ex d Battery Isolator.
  • Bunded base unit.
  • Stainless steel exhaust including spark arrestor.
  • EE x e output hard wire connection point.
  • Certification as per ATEX 94/9/EC

Projects

Project Details

2 X 200kVA Main Power Diesel Generators for use on Unmanned Offshore Installations / NUI in Africa.

  • Africa
  • Diesel Generator
  • Unmanned Platform
↓